Protein rheology measurements

Summary:

Therapeutic protein solutions are highly concentrated during manufacturing purification processes and in finished dosage. At such concentrations, the fluid rheology is complex, creating the need for a convenient accurate method to measure viscosity. Here we develop rheology tools to help evaluate protein stability across a range of solution conditions and protein concentrations that are relevant to manufacturing and product formulation. One tool is a capillary viscometer that requires only a few micro-liters of solution to probe the range of flow rates and temperatures of interest. Another method probes concentrated protein films adsorbed to interfaces where aggregation may take place, and where properties are suspected to correlate with solution stability. Teaming with collaborators, we test industrially relevant materials, evaluate structure and aggregation kinetics, and contribute to the development of an antibody SRM.

Description:

Intended Impact

Why does the health-care industry care about rheology and scattering of protein solutions?

  1. Operations. Viscosity is a critical and fundamental constitutive input for drug delivery, device design and manufacturing. For example, high viscosity leads to poor syringeability due to high injection force required.
  2. Health. Aggregation of mAbs is a potential health risk, and viscosity and scattering measures are diagnostic of aggregation. Our collaborators from U. Delaware (see sidebar) note that the concern here, not yet verified, is whether aggregates may induce adverse immune responses.

This industry therefore needs a convenient method to measure viscosity that avoids potential problems with accuracy and excess sample volume, and which is conveniently part of their quality measurement system. It also needs techniques that can be used to predict protein solution stability, so as to inform molecular design and formulation development. This project is thus developing tools and analyses to measure properties of protein solutions and to identify measures that predict protein solution stability.

Objectives

  • Develop and demonstrate rheology methods and tests that are most predictive and indicative of protein solution instability.
  • Certify viscosity of an antibody SRM (standard reference material) under development.
  • Couple techniques together: rheology/fluorescence; rheology/particle characterization; rheology/neutron scattering.

Technical Approach

Capillary viscometry is a well-established and robust measurement technique. It basically involves measuring a driving pressure and a corresponding flow rate through a capillary. Here the challenge is to make testing very small volumes convenient. Specifically, to measure small flow rates ((0.1 to 100) nL/s), we developed a protocol to optimize the performance and statistics of a commercial microfluidic flow meter. And to quickly handle and load small volumes into the instrument, a micro-pipette simply dips into a standard sample vial. With minor modification, testing multi-well plate sample arrays is feasible. To measure a wide range of viscosity (from (0.5 to 2000) mPa s), we use different pressure sources capable of delivering from 3 Pa to 100,000 Pa, and we employ micro-pipettes of different size.

 Micro capillary viscometer
A photo of the micro capillary viscometer, which uses only microliters of sample.

This method (combined with scattering and other biophysical techniques) is now exploring correlations between viscosity, solution stability and cluster dynamics. Measuring the effects of pH, temperature, and salts is central to improving product yield during concentration of monoclonal antibodies (mAbs) in purification processes. Complex behavior is observed, and in some cases, flow can induce aggregation. The effects of pH and concentration are being measured over a much broader range than previously reported by others. The results demonstrate the failure of existing colloidal rheology models. This result strongly motivates theoretical modeling and model experiment studies.  Specifically, two approaches are in progress: 1.) model colloids that possess simple directional interactions are being tested to find out the properties that deviate from existing models and 2.) a new theoretical model for protein solutions is being developed.

Air-water and oil-water interfaces are present throughout manufacturing and in final protein therapeutic products. The rheology of proteins at these interfaces is of special relevance to aggregation phenomena, because there proteins collect, may slightly denature and begin to aggregate. Interfaces therefore provide a natural model for instability. Unfortunately, interfacial rheology is not widely available, and data is thus sparse. To meet this need, a new method for dilatational interfacial rheology is being adapted for protein solutions, so that it will use smaller volumes and have wider dynamic range. These properties will be measured for a few proteins of interest under a wide range of solution conditions, and compared with bulk aggregation kinetics.

Major Accomplishments:

  • A versatile and accurate micro-viscometer has been developed at NIST and now duplicated at MedImmune. This instrument uses less than 10 uL of fluid, is accurate and precise to a few percent, can measure a two-decade span of shear rate in approx. 10 minutes, and is temperature controlled ((0 – 80) °C). Using this instrument, we demonstrate that various protein antibody solutions may exhibit Newtonian or non-Newtonian rheology, emphasizing the need to measure at a range of shear rate, temperature and other solution conditions.
  • Theoretical calculations of droplet dynamics determine properties from velocity measurements and thus lay a foundation for a new interfacial rheology method.

End Date:

ongoing

Lead Organizational Unit:

mml

Source of Extramural Funding:

MedImmune, in kind support of postdoctoral fellow.

Customers/Contributors/Collaborators:

  • MedImmune (P. Sarangapani and J. A. Pathak), Small volume viscometry
  • Pfizer (S. Kar), Protein stability
  • U. Delaware (J. B. Rovner, C. J. Roberts and E. M. Furst), Protein aggregation and interfacial rheology.

Pharmaceutical companies are crucial contributors, with a deep knowledge and inventory of stable and unstable protein solutions. Rheology, scattering and particle analysis involves other collaborators at NIST.

Facilities/Tools Used:

The microviscometer that we have developed here at NIST is versatile and is being used to test the rheology of other solutions for: organic photovoltaic manufacturing, tissue engineering scaffold materials, body armor, and measuring the effect of directional interactions between suspended particles. Please inquire to pursue an interest.

Staff:

Steven Hudson

John Royer – NRC Postdoctoral Fellow

Related Programs and Projects:

Contact

Steven Hudson, steven.hudson@nist.gov, 301-975-6579
Materials Measurement Lab
Materials Science & Engineering Division
Polymers and Complex Fluids Group
National Institute of Standards and Technology
100 Bureau Dr.
Gaithersburg, MD 20899-8542