NIST logo

Publications Portal

You searched on: Author: W Wyatt Miller

Displaying records 1 to 10 of 23 records.
Resort by: Date / Title


1. Transitioning from mercury thermometers to alternative thermometers
Published: 5/14/2015
Authors: Christina Dawn Cross, W Wyatt Miller, Gregory F Strouse
Abstract: The presentation discusses approaches to effectively transition from mercury thermometers to alternative thermometers with the goal of reducing the level of mercury released into the environment from the disposal or accidental breakage of mercury ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=910009

2. Methods for Accurate Cold-Chain Temperature Monitoring Using Digital Data-Logger Thermometers
Published: 9/11/2013
Authors: Michal J Chojnacky, Gregory F Strouse, W Wyatt Miller
Abstract: Complete and accurate records of vaccine temperature history are vital to preserving drug potency and patient safety. However, previously published vaccine storage and handling guidelines have failed to indicate a need for continuous temperature ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=913639

3. Uncertainty Budget for the NIST Hybrid Humidity Generator
Published: 12/1/2012
Authors: Christopher W Meyer, W Wyatt Miller, Dean C Ripple, Gregory E Scace
Abstract: We provide here a detailed uncertainty budget for the new Hybrid Humidity Generator (HHG) that has been constructed at the National Institute of Standards and Technology (NIST). The HHG generates frost/dew points from ‹70 °C to +85 °C using calibrat ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=905221

4. A Humidity Generator for Temperatures to 200 °C and Pressures to 1.6 MPa
Published: 11/30/2012
Authors: D Vega-Maza, W Wyatt Miller, Dean C Ripple, Gregory E Scace
Abstract: We have constructed a new humidity generator that produces gas streams of known moisture content at temperatures from 85 °C to 200 °C, absolute pressures from 0.2 MPa to 1.6 MPa, and relative humidities from 10 % to 90 %. The generator produces a moi ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=905234

5. Thermal Analysis of Refrigeration Systems Used for Vaccine Storage: Report on Pharmaceutical Grade Refrigerator and Household Refrigerator/Freezer
Series: NIST Interagency/Internal Report (NISTIR)
Published: 8/2/2012
Authors: Michal J Chojnacky, W Wyatt Miller
Abstract: Each year, billions of dollars of vaccines are stored in refrigerators at the facilities of a variety of medical providers. Many vaccines must be maintained in the range 2 °C to 8 °C to retain product potency. We have tested the performance of two ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=907377

6. Thermal Analysis of Refrigeration Systems Used for Vaccine Storage
Series: NIST Interagency/Internal Report (NISTIR)
Report Number: 7656
Published: 11/2/2009
Authors: Michal J Chojnacky, W Wyatt Miller, Dean C Ripple, Gregory F Strouse
Abstract: Each year, billions of dollars of vaccines are stored in refrigerators at the facilities of a variety of medical providers. Many vaccines must be maintained in the range 2 °C to 8 °C to retain product potency. We have tested the performance of two t ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=904574

7. Design and Performance of the New NIST Hybrid Humidity Generator
Published: 6/1/2009
Authors: Christopher W Meyer, W Wyatt Miller, Dean C Ripple, Gregory E Scace
Abstract: A new humidity generator has been constructed at the National Institute of Standards and Technology and is now fully operational. The NIST Hybrid Humidity Generator (HHG) has replaced the Two-Pressure (2-P) Humidity Generator Mark II as the NIST prim ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=904099

8. Calibration of Hygrometers with the Hybrid Humidity Generator
Series: Special Publication (NIST SP)
Published: 12/14/2008
Authors: Christopher W Meyer, Joseph Terence Hodges, Peter H. Huang, W Wyatt Miller, Dean C Ripple, Gregory E Scace
Abstract: We describe here the calibration of customer hygrometers using a new humidity generator that has been commissioned at the National Institute of Standards and Technology. The NIST Hybrid Humidity Generator (HHG) generates frost/dew points from ‹ ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=832432

9. Design and Performance of the new NIST Hybrid Humidity Generator
Published: 8/1/2008
Authors: Christopher W Meyer, W Wyatt Miller, Dean C Ripple, Gregory E Scace
Abstract: A new humidity generator has been constructed at the National Institute of Standards and Technology. Once fully operational, the NIST Hybrid Humidity Generator (HHG) will replace the Two-Pressure (2-P) Humidity Generator Mark II as the NIST primary ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=832270

10. Frequency-Stabilized Single-Mode Cavity Ring-Down Apparatus for High-Resolution Absorption Spectroscopy
Published: 4/1/2004
Authors: Joseph Terence Hodges, Howard P. Layer, W Wyatt Miller, Gregory E Scace
Abstract: We present a new cavity ring-down spectroscopy (CRDS) apparatus suitable for high-resolution absorption spectroscopy. The central feature of the spectrometer is a ring-down cavity whose comb of eigenfrequencies is actively stabilized with respect to ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=830867



Search NIST-wide:


(Search abstract and keywords)


Last Name:
First Name:







Special Publications:

Looking for a NIST Special Publication (NIST SP Series)? Place the series number and dash in the report number field (Example: 800-) and begin your search.

  • SP 250-XX: Calibration Services
  • SP 260-XX: Standard Reference Materials
  • SP 300-XX: Precision Measurement and Calibration
  • SP 400-XX: Semiconductor Measurement Technology
  • SP 480-XX: Law Enforcement Technology
  • SP 500-XX: Computer Systems Technology
  • SP 700-XX: Industrial Measurement Series
  • SP 800-XX: Computer Security Series
  • SP 823-XX: Integrated Services Digital Network Series