Name | Plant_21
|
---|---|
Date | |
Description | Excelsior; vertical orientation; single specimen; Bottom ignition; height = 60 cm; width = 15 cm; mass = 59 g (wet basis); moisture content = 6 % (dry basis); bulk density = 6 kg/m3 |
Specimen | Excelsior
|
Ignition | 164 W dual tip propane wand for 5 sec
|
Project ID (s) | |
Test Director | Hamins
|
Measurement | Value | Uc | Unit |
---|---|---|---|
Peak Heat Release Rate, PHRR
|
76.0
|
3.9
|
kW
|
Time to Peak Heat Release Rate
|
0.18
|
0.07
|
min
|
Total Heat Released, THR
|
1.005
|
0.056
|
MJ
|
Gas Burner Total Heat Released, NGTHR
|
0
|
- | MJ
|
Heat Release Quality Confirmation, HRQC
|
Not measured | - | MJ/MJ
|
Net Specimen Mass (gravimetric), NM = Mi-Mf
|
0.0558
|
0.0016
|
kg
|
Net Effective Heat of Combustion = THR / NM
|
18.0
|
1.1
|
MJ/kg
|
O2 Yield = O2 Consumed / NM
|
1.377
|
0.059
|
kg/kg
|
CO2 Yield = CO2 Generated / NM
|
1.792
|
0.082
|
kg/kg
|
CO Yield = CO Generated / NM
|
0.0391
|
0.0018
|
kg/kg
|
Soot Yield = Soot Generated / NM
|
0.00160
|
0.00023
|
kg/kg
|
Baseline Hood Exhaust Flow
|
0.948
|
0.028
|
kg/s
|
Test Duration = Time(Fire Out) - Time(Ignition)
|
1.30
|
0.03
|
min
|
Uc = Combined Expanded Uncertainty with 95% confidence level
Parameter | Value | Uc | Unit |
---|---|---|---|
Fuel Type
|
Excelsior
|
- | - |
Hood Size
|
3
|
- | m
|
Effective Duct Diameter
|
0.483
|
0.004
|
m
|
Exhaust Flow Correction Factor
|
1.033
|
0.029
|
- |
Net Heat of Combustion (per unit mass O2), Ef
|
13.23
|
0.53
|
MJ/kg
|
Net Heat of Combustion(per unit mass fuel), HOCf
|
18.00
|
0.50
|
MJ/kg
|
Initial Specimen Mass, Mi (gravimetric)
|
0.06
|
0.00
|
kg
|
Final Specimen Mass, Mf (gravimetric)
|
below detection limit
|
0.00
|
kg
|
Event | Time (min) | Description | Video Snapshot Image |
---|---|---|---|
1
|
0.00
|
Ignition
|
![]() |
peak
|
0.18
|
Peak HRR
|
![]() |
2
|
1.30
|
Fire Out
|
![]() |
Bryant, R. and Bundy, M. The NIST 20 MW Calorimetry Measurement System for Large-Fire Research, Technical Note (NIST TN) 2077, 2019
https://doi.org/10.6028/NIST.TN.2077
NIST Fire Calorimetry Database (FCD)
https://doi.org/10.18434/mds2-2314