Name | stovetop_test_MassLoss_13
|
---|---|
Date | |
Description | Brown Stove Control of small burner (Right Rear), about 150 g corn oil; two TCs monitoring pan bottom, TC3, TC4, TC5 off bottom 1 mm, 9mm and 19 mm, Heat Flux at `131 cm from pan center and 20 cm above heating element, Scale mass loss, HRR, video, heating element on, Bldg 205, autoignition |
Specimen | cooking pan
|
Ignition | heating element
|
Project ID (s) | |
Test Director | Hamins
|
Measurement | Value | Uc | Unit |
---|---|---|---|
Peak Heat Release Rate, PHRR
|
73.7
|
3.3
|
kW
|
Time to Peak Heat Release Rate
|
3.15
|
0.17
|
min
|
Total Heat Released, THR
|
5.59
|
0.28
|
MJ
|
Natural Gas Burner Total Heat Released, NGTHR
|
0
|
- | MJ
|
Heat Release Quality Confirmation, HRQC
|
Not measured | - | MJ/MJ
|
Net Specimen Mass (gravimetric), NM = Mi-Mf
|
Not measured | - | kg
|
Total Fuel Mass Burned, TFM = THR / HOCf
|
0.1498
|
0.0096
|
kg
|
Net Effective Heat of Combustion = THR / NM
|
Not measured | - | MJ/kg
|
O2 Yield = O2 Consumed / TFM
|
2.22
|
0.16
|
kg/kg
|
CO2 Yield = CO2 Generated / TFM
|
2.32
|
0.17
|
kg/kg
|
CO Yield = CO Generated / TFM
|
below detection limit
|
0.00041
|
kg/kg
|
Soot Yield = Soot Generated / TFM
|
Not measured | - | kg/kg
|
Baseline Hood Exhaust Flow
|
2.084
|
0.063
|
kg/s
|
Test Duration = Time(Fire Out) - Time(Ignition)
|
4.63
|
0.03
|
min
|
Uc = Combined Expanded Uncertainty with 95% confidence level
Parameter | Value | Uc | Unit |
---|---|---|---|
Fuel Type
|
Corn Oil
|
- | - |
Hood Size
|
3
|
- | m
|
Effective Duct Diameter
|
0.485
|
0.004
|
m
|
Exhaust Flow Correction Factor
|
1.033
|
0.029
|
- |
Net Heat of Combustion (per unit mass O2), Ef
|
13.40
|
0.40
|
MJ/kg
|
Net Heat of Combustion(per unit mass fuel), HOCf
|
37.30
|
1.50
|
MJ/kg
|
Initial Specimen Mass, Mi (gravimetric)
|
Not measured | - | kg
|
Final Specimen Mass, Mf (gravimetric)
|
Not measured | - | kg
|
Event | Time (min) | Description | Video Snapshot Image |
---|---|---|---|
1
|
-27.20
|
heating element on
|
|
2
|
0.00
|
Ignition
|
|
peak
|
3.15
|
Peak HRR
|
|
3
|
4.63
|
Fire Out
|
Bryant, R. and Bundy, M. The NIST 20 MW Calorimetry Measurement System for Large-Fire Research, Technical Note (NIST TN) 2077, 2019
https://doi.org/10.6028/NIST.TN.2077
NIST Fire Calorimetry Database (FCD)