Name | Test054_CanvasTarp12x12_R2
|
---|---|
Date | |
Description | Duck Canvas Tarp, hung 36 in off pan. Ignition=wick soaked w/ 5 mL heptane |
Specimen | canvas tarp
|
Ignition | heptane wick
|
Project ID (s) | |
Test Director | McGrattan
|
Measurement | Value | Uc | Unit |
---|---|---|---|
Peak Heat Release Rate, PHRR
|
612
|
27
|
kW
|
Time to Peak Heat Release Rate
|
5.57
|
0.17
|
min
|
Total Heat Released, THR
|
52.5
|
2.4
|
MJ
|
Gas Burner Total Heat Released, NGTHR
|
0
|
- | MJ
|
Heat Release Quality Confirmation, HRQC
|
Not measured | - | MJ/MJ
|
Net Specimen Mass (gravimetric), NM = Mi-Mf
|
3.471
|
0.028
|
kg
|
Net Effective Heat of Combustion = THR / NM
|
15.13
|
0.71
|
MJ/kg
|
O2 Yield = O2 Consumed / NM
|
1.139
|
0.038
|
kg/kg
|
CO2 Yield = CO2 Generated / NM
|
1.499
|
0.055
|
kg/kg
|
CO Yield = CO Generated / NM
|
0.02565
|
0.00095
|
kg/kg
|
Soot Yield = Soot Generated / NM
|
0.00097
|
0.00015
|
kg/kg
|
Baseline Hood Exhaust Flow
|
3.080
|
0.092
|
kg/s
|
Test Duration = Time(Fire Out) - Time(Ignition)
|
8.62
|
0.03
|
min
|
Uc = Combined Expanded Uncertainty with 95% confidence level
Parameter | Value | Uc | Unit |
---|---|---|---|
Fuel Type
|
Cellulose
|
- | - |
Hood Size
|
3
|
- | m
|
Effective Duct Diameter
|
0.485
|
0.005
|
m
|
Exhaust Flow Correction Factor
|
1.033
|
0.029
|
- |
Net Heat of Combustion (per unit mass O2), Ef
|
13.61
|
0.41
|
MJ/kg
|
Net Heat of Combustion(per unit mass fuel), HOCf
|
16.12
|
0.60
|
MJ/kg
|
Initial Specimen Mass, Mi (gravimetric)
|
3.43
|
0.02
|
kg
|
Final Specimen Mass, Mf (gravimetric)
|
below detection limit
|
0.02
|
kg
|
Event | Time (min) | Description | Video Snapshot Image |
---|---|---|---|
1
|
0.00
|
Ignition
|
|
peak
|
5.57
|
Peak HRR
|
|
2
|
8.62
|
Fire Out
|
Bryant, R. and Bundy, M. The NIST 20 MW Calorimetry Measurement System for Large-Fire Research, Technical Note (NIST TN) 2077, 2019
https://doi.org/10.6028/NIST.TN.2077
NIST Fire Calorimetry Database (FCD)
https://doi.org/10.18434/mds2-2314