In the RapidVap N2, a stream of nitrogen or dry gas is directed downward onto the surface of the sample. This reduces the partial pressure directly over the
Access Information Refrigerators and freezers are available in the laboratories for storing temperature sensitive samples shortly before, during and shortly
Access Information Refrigerators and freezers are available in the laboratories for storing temperature sensitive samples shortly before, during and shortly
The Large Aperture Scanner (LAS) scans a radar transceiver over a 5 meter by 20 meter aperture. Image reconstruction techniques enable a three-dimensional
In contrast to scanning transmission X-ray microscopy (STXM), the Large Area Rapid Imaging Tool provides full field imaging capabilities over a relatively large
In contrast to scanning transmission X-ray microscopy (STXM), the Large Area Rapid Imaging Tool provides full field imaging capabilities over a relatively large
Since 2006, the Nanomechanical Properties Group has pioneered the use of Laser Doppler Vibrometry (LDV) to calibrate the stiffness of AFM cantilevers using the
This apparatus, developed at EL, determines material properties related to piloted ignition of a vertically oriented sample under constant and uniform heat flux
Large bowl-shaped process chamber to reduce turbulence and eliminate splash back while spin coating A seamless copolymer housing Precise and repeatable
Leak artifacts are calibrated in the range 1 x 10 -6 to 1 x 10 -13 mol/s (2 x 10 -2 to 2 x 10 -9 std. cm 3/s at 0 °C). The calibration can be performed directly
The 1-meter guarded hot-plate apparatus measures thermal conductivity of building insulation. This facility provides for absolute measurement of thermal
The Fluid Metrology Group developed a dual-purpose, automated apparatus to calibrate hydrometers via Cuckow’s method and to also measure the density of
The Fluid Metrology Group has four liquid flow standards spanning the flow range 0.002 L/s to 65 L/s with uncertainties less than 0.06 % at a 95 % confidence
The little red magnet (LRM) can be oriented so that the magnetic field is parallel or perpendicular to the direction of the neutron beam and the maximum field