Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Throw_pillow_2

Table 1. Test Information
Name
Throw_pillow_2
Date
Description

30 mm propane diffution flame ignition applied to lower side of 45 cm (18 inch) blue fabric throw pillow for 30 sec. Burn to completion.

Specimen
Throw Pillow
Ignition
propane wand
Project ID (s)
Test Director
Zammarano

Timelapse Video with Heat Release Rate Plot

Table 2. Summary of Test Results
Measurement Value Uc Unit
Peak Heat Release Rate, PHRR
45.0
2.5
kW
Time to Peak Heat Release Rate
2.73
0.17
min
Total Heat Released, THR
4.20
0.26
MJ
Natural Gas Burner Total Heat Released, NGTHR
0
-
MJ
Heat Release Quality Confirmation, HRQC
Not measured -
MJ/MJ
Net Specimen Mass (gravimetric), NM = Mi-Mf
0.2880
0.0028
kg
Net Effective Heat of Combustion = THR / NM
14.60
0.91
MJ/kg
O2 Yield = O2 Consumed / NM
1.293
0.043
kg/kg
CO2 Yield = CO2 Generated / NM
1.786
0.067
kg/kg
CO Yield = CO Generated / NM
0.0375
0.0014
kg/kg
Soot Yield = Soot Generated / NM
0.0587
0.0075
kg/kg
Baseline Hood Exhaust Flow
2.056
0.062
kg/s
Test Duration = Time(Fire Out) - Time(Ignition)
6.65
0.03
min

Uc = Combined Expanded Uncertainty with 95% confidence level

Table 3. Summary of Test Input Parameters
Parameter Value Uc Unit
Fuel Type
Polyester
- -
Hood Size
3
-
m
Effective Duct Diameter
0.483
0.004
m
Exhaust Flow Correction Factor
1.033
0.029
-
Net Heat of Combustion (per unit mass O2), Ef
11.90
0.47
MJ/kg
Net Heat of Combustion(per unit mass fuel), HOCf
24.00
0.70
MJ/kg
Initial Specimen Mass, Mi (gravimetric)
0.50
0.00
kg
Final Specimen Mass, Mf (gravimetric)
0.21
0.00
kg
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Figure 1. Plot of Heat Release Rate data with event markers and error bars shown at peak.
Table 4. Summary of Observed Test Events
Event Time (min) Description Video Snapshot Image
1
0.00
Ignition
Ignition
2
0.20
Burner off
Burner off
peak
2.73
Peak HRR
Peak HRR
3
6.65
Fire Out
Fire Out

Table 5. Supplemental Data Plots

Plot of Oxygen Dry Volume Fraction in hood exhaust stream.
Plot of Oxygen Dry Volume Fraction in hood exhaust stream.
Plot of Carbon Dioxide Dry Volume Fraction in hood exhaust stream.
Plot of Carbon Dioxide Dry Volume Fraction in hood exhaust stream.
Plot of Carbon Monoxide Dry Volume Fraction in hood exhaust stream.
Plot of Carbon Monoxide Dry Volume Fraction in hood exhaust stream.
Plot of Radiant Heat Flux data with event markers. r= radial distance from center of hood, h=height above floor.
Plot of Radiant Heat Flux data with event markers. r= radial distance from center of hood, h=height above floor.
Plot of Smoke Laser Extinction Coefficient in hood exhaust stream.
Plot of Smoke Laser Extinction Coefficient in hood exhaust stream.
Plot of Exhaust Duct Mass Flow Rate.
Plot of Exhaust Duct Mass Flow Rate.

Bryant, R. and Bundy, M. The NIST 20 MW Calorimetry Measurement System for Large-Fire Research, Technical Note (NIST TN) 2077, 2019
https://doi.org/10.6028/NIST.TN.2077

NIST Fire Calorimetry Database (FCD)
https://doi.org/10.18434/mds2-2314

Report Process Script Version
NFRL_Report_8.3.3
Last Updated May 14, 2021