An official website of the United States government
Here’s how you know
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
Secure .gov websites use HTTPS
A lock (
) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.
Improved Normalization of Systematic Biases Affecting Ion Current Measurements in Label-free Proteomics Data
Published
Author(s)
Paul A. Rudnick, Xinjian Yan, Stephen E. Stein, Xia Wang, Nell Sedransk
Abstract
Systematic biases, or batch effects, in high-throughput biological datasets can be described as obscuring variabilities introduced during experimental design or analytical processing. These biases, if left unresolved, can lead to misinterpretation of results. Batch effects in microarray experiments are well documented, and statistical methods for their removal (e.g., normalization) have been developed. But, in general, much less attention has been given to this topic in MS-based proteomics, particularly in understanding their underlying causes. Label-free proteomic data present a particularly challenging case since signals from separate LC-MS runs are compared. This differs from labeling experiments in which 2 or more differently labeled samples are mixed and analyzed in a single LC run. In this work, we examined the multi-laboratory datasets from the first phase of NCIs CPTAC program, in which systematic biases were identified by monitoring signals arising from individual peptide ions. Surprisingly, the largest biases within labs were retention time and charge state, not intensity as is typically used during normalization. These effects were exaggerated in samples of unequal concentrations or spike-in levels. Our analysis indicates that the average precursor charge for peptides with higher charge state potentials is lower at higher sample concentrations. These effects are consistent with reduced relative protonation during ESI and demonstrate that the physical properties of the peptides themselves can serve as good reporters of systematic biases. Between labs, intensity was most commonly the top-ranked bias variable, over retention time, precursor m/z and . A larger set of variables was then used to develop a stepwise normalization procedure. This statistical model was found to perform as well or better on the CPTAC mock biomarker data than other commonly used methods, and it does not require a priori knowledge of the systematic biases in a give
Rudnick, P.
, Yan, X.
, Stein, S.
, Wang, X.
and Sedransk, N.
(2014),
Improved Normalization of Systematic Biases Affecting Ion Current Measurements in Label-free Proteomics Data, Molecular and Cellular Proteomics, [online], https://doi.org/10.1074/mcp.M113.030593
(Accessed April 3, 2025)