Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

The Metrology of a Rastered Spot of X Rays used in Security Screening

Published

Author(s)

Lawrence T. Hudson, Jack L. Glover, Ronaldo Minniti

Abstract

In recent times, ionizing radiation has been used around the world to screen persons for non- medical purposes, namely to detect bulk explosives or other contraband hidden on the body including materials not registered by metal detectors. In contrast to conventional transmission or projection imaging, backscatter and forward-scatter systems employ a “flying spot” of x rays and large-area detectors. A small spot is rastered across an individual and the Compton scatter signal collected by these detectors is quickly integrated and assigned to a pixel value in an image corresponding to the transient location of the small flying spot. These systems have been controversial due to expressed concerns about loss of privacy, cost benefit, effectiveness to detect or deter threats, radiation health risks, and lack of independent and accurate measurements of radiation exposures to the subjects, bystanders, and operators of such systems. In this paper we will outline the techniques and instrumentation used at the National Institute of Standards and Technology (NIST) to accurately determine the incident air kerma from a swept beam of x rays. We discuss in detail the response of a large-area free-air ionization chamber under the unusual temporal and spatial radiation fields delivered by commercial scanning systems and report typical values for air kerma levels as well as estimates of air kerma rates.
Citation
Journal of Research (NIST JRES) - 119.021
Report Number
119.021
Volume
119

Keywords

dosimetry, rastered beam, swept beam, x rays, backscatter, security screening, ionization chamber, air kerma, air kerma rate, advanced imaging technology

Citation

Hudson, L. , Glover, J. and Minniti, R. (2014), The Metrology of a Rastered Spot of X Rays used in Security Screening, Journal of Research (NIST JRES), National Institute of Standards and Technology, Gaithersburg, MD, [online], https://doi.org/10.6028/jres.119.021 (Accessed November 21, 2024)

Issues

If you have any questions about this publication or are having problems accessing it, please contact reflib@nist.gov.

Created November 6, 2014, Updated November 10, 2018