Displaying 201 - 225 of 291

Performance Data on Cold Temperature Dispersion of CF3I

May 2, 2000
Author(s)
Jiann C. Yang, Thomas G. Cleary, Michelle K. Donnelly
Tritluoroiodomethane (CF3I) has been proposed as a potential replacement for Halon 1301 in aircraft engine nacelle and dry bay fire protection applications. The potential use of CF3I in fuel tank ullage inerting has also been considered recently. Before

Particulate Entry Lag in Spot-Type Smoke Detectors

July 5, 1999
Author(s)
Thomas G. Cleary, Artur A. Chernovsky, William L. Grosshandler, Michael D. Anderson
It is well documented that alarm signals from spot-type smoke detectors (ionization and photoelectric) are delayed when the threshold value has been achieved outside the detector housing as a result of convective transport of smoke through the detector to

Evaluating Multi-Sensor Fire Detectors in the Fire Emulator/Detector Evaluator

June 29, 1999
Author(s)
Thomas G. Cleary, Michael D. Anderson, Jason D. Averill, William L. Grosshandler
NIST has developed the Fire Emulator/Detector Evaluator (FE/DE) for the purpose of testing detectors in a controlled environment. The FE/DE is a flow tunnel where fire or nuisance source characteristics can be controlled so that a detector placed in the FE

Smoke Detector Response to Nuisance Aerosols

March 16, 1999
Author(s)
Thomas G. Cleary, William L. Grosshandler, Artur A. Chernovsky
The worth of a fire detector is determined as much by its ability not to respond to stimuli that are generated from non-threatening sources as to respond in a timely manner to an actual fire. Photo-electric and ionization smoke detectors react to a greater

Upward Flame Spread on Composite Materials

January 1, 1999
Author(s)
Thomas J. Ohlemiller, Thomas G. Cleary
Three existing models of upward flame spread were tested against intermediate-scale experiments on a vinyl-ester/glass composite. Characterization of rate of heat release per unit area, needed as input to the models, was obtained at external radiant fluxes

Fire-Emulator Detector-Evaluation

October 28, 1998
Author(s)
Artur A. Chernovsky, William L. Grosshandler, Thomas G. Cleary, Michael D. Anderson
The performance of a fire detection system is determined as much by its ability to recognize correctly the non-fire state as to sense the presence of a real fire. Common fire detectors respond to particulate matter in the form of smoke from a flaming or

Influence of Surface Silica on the Pyrolysis of Silicones (NISTIR 6242)

October 1, 1998
Author(s)
R R. Buch, John R. Shields, Takashi Kashiwagi, Thomas Cleary, Kenneth D. Steckler
Silicones encompass a wide variety of noval materials that find applications in virtually every major industry sector. The dominant polymer in the silicone industry is polydimethylsiloxane (PDMS). The combustion of long chain PDMS exhibits a low heat

Particulate Entry Lag in Smoke Detectors (NISTIR 6242)

October 1, 1998
Author(s)
Thomas G. Cleary, Artur A. Chernovsky, William L. Grosshandler, Michael D. Anderson
It is well known that smoke detectors do not instantaneously respond to smoke concentration directly outside the detector. The smoke must be transported through the detector housing to a sensing location inside the detector. The sensing time lag is a