The Redefinition of the SI: Impact on Calibration Services at NIST

June 1, 2015
Author(s)
Neil M. Zimmerman, Jon R. Pratt, Michael R. Moldover, David B. Newell, Gregory F. Strouse
As most readers are probably at least vaguely aware, it is likely that the SI system of units will be redefied in 2018. This redefinition would fundamentally change the logical structure of the SI, with one result being a substantial change in how mass is

Transitioning from mercury thermometers to alternative thermometers

May 14, 2015
Author(s)
Christina D. Cross, W Wyatt Miller, Gregory F. Strouse
The presentation discusses approaches to effectively transition from mercury thermometers to alternative thermometers with the goal of reducing the level of mercury released into the environment from the disposal or accidental breakage of mercury

In-situ Temperature Calibration Capability for Dimensional Metrology

December 15, 2014
Author(s)
Prem K. Rachakonda, Daniel S. Sawyer, Balasubramanian Muralikrishnan, Christopher J. Blackburn, Craig M. Shakarji, Gregory F. Strouse, Steven D. Phillips
The Dimensional Metrology Group (DMG) at the National Institute of Standards and Technology (NIST) has developed a new in-situ temperature calibration system. This paper discusses the system components, an in-situ calibration procedure, the uncertainty

In-situ Temperature Calibration Capability for Dimensional Metrology

December 1, 2014
Author(s)
Prem K. Rachakonda, Daniel S. Sawyer, Balasubramanian Muralikrishnan, Christopher J. Blackburn, Craig M. Shakarji, Gregory F. Strouse, Steven D. Phillips
The Dimensional Metrology Group (DMG) at the National Institute of Standards and Technology (NIST) has the capability to perform large range dimensional measurements in a facility, called the Tape Tunnel. The Tape Tunnel is equipped with a 60 m long steel

In Search of Better Pressure Standards

August 1, 2014
Author(s)
Jay H. Hendricks, Jacob E. Ricker, Patrick F. Egan, Gregory F. Strouse
Based on highly accurate optical interferometry and fundamental quantum calculations, researchers at the National Institute of Standards and Technology (NIST) in the US are developing an improved definition of the SI unit for pressure that will consign the

Metrology for comparison of displacements at the picometer level

July 31, 2014
Author(s)
Jack A. Stone Jr., Patrick F. Egan, Jay H. Hendricks, Gregory F. Strouse, Douglas A. Olson, Jacob E. Ricker, Gregory E. Scace, Donavon Gerty
An apparatus capable of comparing displacements with picometer accuracy is currently being designed at NIST. In principle, we wish to compare one displacement in vacuum to a second, equal displacement in gas, in order to determine gas refractive index. If

Effect of Impurities on Water Triple Point Cells

July 15, 2014
Author(s)
A Peruzzi, J. van Geel, A. Uytun, M. Kalemci, E. Uysal, Gregory F. Strouse, Yoana Y. Nuevo Ordonez, William Davis
Water triple point cells are the basis for the definition of the Kelvin and for the realization of the International Temperature Scale of 1990. The temperature differences between the cells are mainly caused by impurities arising in the cell water from the

Ultra-Sensitive Chip-Based Photonic Temperature Sensor Using Ring Resonator Structures

February 3, 2014
Author(s)
Haitan Xu, Mohammad Hafezi, Jingyun Fan, Jacob Taylor, Gregory F. Strouse, Zeeshan Ahmed
Temperature is one of the most measured quantity in the world, second only to time. Recently there has been considerable interest in developing photonic temperature sensors to leverage advancements in frequency metrology. Here we show that Silicon based

Picometer Metrology for Precise Measurement of Refractive Index, Pressure, and Temperature

December 18, 2013
Author(s)
Jack A. Stone Jr., Patrick F. Egan, Donavon Gerty, Jay H. Hendricks, Douglas A. Olson, Jacob E. Ricker, Gregory E. Scace, Gregory F. Strouse
Fabry-Perot interferometers can be used for very precise measurement of the refractive index of gasses. This can enable increased accuracy of interferometer-based length measurement. In addition, because the refractive index of a gas depends on its

Picometer metrology for precise measurement of refractive index, pressure, and temperature

July 14, 2013
Author(s)
Jack A. Stone Jr., Patrick F. Egan, Jay H. Hendricks, Gregory F. Strouse, Douglas A. Olson, Jacob E. Ricker, Gregory E. Scace
For several years we have been studying the use of Fabry-Perot interferometers for precise measurement of the refractive index of gasses, where the primary motivation has been to improve interferometer-based length measurement. Because the refractive index