Search Publications by: Carl D. Reintsema (Fed)

Search Title, Abstract, Conference, Citation, Keyword or Author
Displaying 76 - 100 of 228

Optimization of the TES-bias circuit for a multiplexed microcalorimeter array

January 27, 2012
Author(s)
William B. Doriese, Bradley K. Alpert, Joseph W. Fowler, Gene C. Hilton, Alex S. Hojem, Kent D. Irwin, Carl D. Reintsema, Daniel R. Schmidt, Greg Stiehl, Daniel S. Swetz, Joel N. Ullom, Leila R. Vale
In the detector-bias circuit of a transition-edge-sensor (TES) microcalorimeter, the TES-shunt resistor (Rsh) and the thermal conductance to the cryogenic bath (G) are often considered to be interchangeable knobs with which to control detector speed

A High Resolution High-Sensitivity Standoff Imaging System at 350 GHz

May 23, 2011
Author(s)
Daniel T. Becker, Cale Gentry, James A. Beall, Hsiao-Mei Cho, William Duncan, Gene C. Hilton, Kent D. Irwin, Peter J. Lowell, Michael D. Niemack, Nicholas G. Paulter Jr., Carl D. Reintsema, Francis J. Schima, Robert E. Schwall, Peter Ade, Carole Tucker, Simon Dicker, Halpern Mark
Millimeter wavelength radiation holds promise for detection of security threats at a distance, including suicide bomb belts and maritime threats in poor weather conditions. The sensitivity provided by superconducting Transition-Edge-Sensor (TES) bolometers

Time-division SQUID multiplexers with reduced sensitivity to external magnetic fields

November 29, 2010
Author(s)
Greg Stiehl, Hsiao-Mei Cho, Gene C. Hilton, Kent D. Irwin, John A. Mates, Carl D. Reintsema, Barry L. Zink
We have developed time-division SQUID multiplexers to read out large arrays of transition-edge sensor (TES) detectors. These multiplexers are used in many applications that require exquisite control of systematic error. One important application is the

A 350-GHz high-resolution high-sensitivity passive video imaging system

April 27, 2010
Author(s)
Daniel T. Becker, James A. Beall, Hsiao-Mei Cho, William Duncan, Kent D. Irwin, Gene C. Hilton, Robert D. Horansky, Peter J. Lowell, Michael D. Niemack, Nicholas G. Paulter Jr., Carl D. Reintsema, Francis J. Schima, Robert E. Schwall, Ki W. Yoon, Peter Ade, Carole Tucker, Simon Dicker, Mark Halpern
We are developing a 350 GHz cryogenic passive video imaging system. This demonstration system uses 800 photon-noise-limited superconducting transition edge sensor bolometers. It will image a 1 m x 1 m area at a standoff distance of 16 m to a resolution of

Code-division SQUID multiplexing

April 23, 2010
Author(s)
Michael D. Niemack, Kent D. Irwin, Joern Beyer, Hsiao-Mei Cho, William B. Doriese, Gene C. Hilton, Carl D. Reintsema, Daniel R. Schmidt, Joel N. Ullom, Leila R. Vale
Multiplexed superconducting quantum interference device (SQUID) readout systems are a critical technology for measuring large arrays of superconducting transition-edge sensor (TES) detectors. Current successful SQUID multiplexing architectures are

Superconductor Science and Technology

February 22, 2010
Author(s)
Kent D. Irwin, Michael D. Niemack, Joern Beyer, Hsiao-Mei Cho, William B. Doriese, Gene C. Hilton, Carl D. Reintsema, Daniel R. Schmidt, Joel N. Ullom, Leila R. Vale
Multiplexed superconducting quantum interference device (SQUID) amplifiers have recently enabled the deployment of kilopixel arrays of superconducting transition-edge sensor (TES) detectors on a variety of receivers for astrophysics. Existing multiplexing

Electronics for a Next-Generation SQUID-Based Time-Domain Multiplexing System

December 16, 2009
Author(s)
Carl D. Reintsema, Gene C. Hilton, Kent D. Irwin, Joseph S. Adams, Robert Baker, Simon R. Bandler, William B. Doriese, Enectali Figueroa-Feliciano, Richard L. Kelly, Caroline A. Kilbourne, F. S. Porter, Jeff Krinsky, Patrick Wikus
A decade has elapsed since the design, development and realization of a SQUID-based time-division multiplexer at NIST. During this time the system has been used extensively for low-temperature-detector-array measurements. Concurrently, there have been

An Optical System for Body Imaging from a Distance Using near-TeraHertz Frequencies

January 26, 2008
Author(s)
William Duncan, Robert E. Schwall, Kent D. Irwin, James A. Beall, Carl D. Reintsema, W.Bertrand (Randy) Doriese, Hsiao-Mei Cho, Brian Estey, Goutam Chattopadhyay, Peter Ade, Carole Tucker
We present the outline of the optical design of a TeraHertz (THz) imager for the detection of shrapnel-loaded improvised explosive devices (IED''s) at ''stand-off'' distances of 14 - 26 meters. The system will use 4 antenna-coupled TES detector arrays of

A TDMA Hybrid SQUID Multiplexer

January 25, 2008
Author(s)
Carl D. Reintsema, James A. Beall, W.Bertrand (Randy) Doriese, William Duncan, S. L. Ferreira, Gene C. Hilton, Kent D. Irwin, Dan Schmidt, Joel Ullom, Leila R. Vale, Yizi Xu
We have developed a multiplexed read-out for transition edge sensors based on a hybrid time- and frequency-domain basis set, similar to that used in time-division multiple-access (TDMA) mobile phones. The hybrid basis set uses bandwidth more efficiently

Large array of multiplexed gamma-ray microcalorimeters for nuclear-materials analysis

January 24, 2008
Author(s)
W.Bertrand (Randy) Doriese, Joel Ullom, James A. Beall, William Duncan, S. L. Ferreira, Gene C. Hilton, Rob Horansky, Kent D. Irwin, John Mates, Carl D. Reintsema, Dan Schmidt, Leila R. Vale, Yizi Xu, Barry L. Zink, Michael W. Rabin, Minesh K. Bacrania, Stephen Lamont, Andrew Hoover, Clifford R. Rudy, Duc Vo, C. K. Stahle, Kevin R. Boyce, Larry E. Brown, Jonathan M. King, F. S. Porter
We are developing a gamma-ray spectrometer for the analysis of nuclear materials based on an array of superconducting transition-edge-sensor microcalorimeters. The instrument includes eight columns of time-division-SQUID multiplexing circuitry capable of

Multiplexed microcalorimeter arrays for precision measurements from microwave to gamma-ray wavelengths

August 21, 2007
Author(s)
Joel Ullom, W.Bertrand (Randy) Doriese, James A. Beall, William Duncan, S. L. Ferreira, Gene C. Hilton, Rob Horansky, Kent D. Irwin, Terrence J. Jach, John Mates, Nathan A. Tomlin, Galen O'Neil, Carl D. Reintsema, Nicholas Ritchie, Dan Schmidt, Leila R. Vale, Yizi Xu, Barry L. Zink, Andrew Hoover, Clifford R. Rudy, Derek Tournear, Duc Vo, Michael W. Rabin
Cryogenic microcalorimeters are a promising technology for ultrasensitive measurements of electromagnetic radiation from microwave to gamma-ray wavelengths. Cryogenic microcalorimeters derive their exquisite sensitivity from the minimal thermal noise at

A 14-pixel, multiplexed array of gamma-ray microcalorimeters with 47 eV energy resolution at 103 keV

May 9, 2007
Author(s)
W.Bertrand (Randy) Doriese, Joel Ullom, James A. Beall, William Duncan, S. L. Ferreira, Gene C. Hilton, Rob Horansky, Kent D. Irwin, John Mates, Carl D. Reintsema, Leila R. Vale, Yizi Xu, Barry L. Zink, Andrew Hoover, Michael W. Rabin, Clifford R. Rudy, Duc Vo
We present a prototype for a high-energy-resolution, high-count-rate, gamma-ray spectrometer intended for nuclear forensics and international nuclear safeguards. The prototype spectrometer is an array of 14 transition-edge-sensor microcalorimeters with an

Demonstration and modeling of an array-compatible TES microcalorimeter gamma-ray detector with 42 eV energy resolution at 103 keV

September 20, 2006
Author(s)
Barry L. Zink, Joel Ullom, James A. Beall, Kent D. Irwin, W.Bertrand (Randy) Doriese, William Duncan, S. L. Ferreira, Gene C. Hilton, Rob Horansky, Carl D. Reintsema, Leila R. Vale
We describe a microcalorimeter gamma-ray detector with measured energy resolution of 42 eV full width at half maximum for 103 keV photons. This detector consists of a thermally isolated superconducting transition-edge thermometer and a superconducting bulk