Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications by: Dan Schmidt (Fed)

Search Title, Abstract, Conference, Citation, Keyword or Author
Displaying 126 - 150 of 160

Optimization and analysis of code-division multiplexed TES microcalorimeters

January 20, 2012
Author(s)
Joseph W. Fowler, William B. Doriese, Gene C. Hilton, Kent D. Irwin, Daniel R. Schmidt, Greg Stiehl, Daniel S. Swetz, Joel N. Ullom, Leila R. Vale
We are developing code-division multiplexing (CDM) readout systems for TES arrays for good scalability to large multiplexing factors. We report high energy resolution x-ray measurements made through four-channel CDM that employ a flux-summing architecture

Strongly quadrature-dependent noise in superconducting microresonators measured at the vacuum-noise limit

June 9, 2011
Author(s)
Jiansong Gao, Kent D. Irwin, Gene C. Hilton, John A. Mates, Daniel R. Schmidt, Leila R. Vale, Konrad W. Lehnert, Francois Mallet, Jonas Zmuidzinas
We report noise measurement of superconducting micro-resonators with a Josephson parametric amplifier. These resonators show significant amount of frequency noise caused by surface two-level systems. However, in the dissipation quadrature, no excess noise

Al-Mn transition edge sensors for cosmic microwave background polarimeters

November 22, 2010
Author(s)
Daniel R. Schmidt, Hsiao-Mei Cho, Johannes Hubmayr, Peter J. Lowell, Michael D. Niemack, Galen C. O'Neil, Joel N. Ullom, Ki W. Yoon, Kent D. Irwin
Superconducting transition edge sensors (TES) require superconducting films with transition temperatures (Tc)and properties that can be tailored to the particular requirements of individual applications. We have been developing Al-Mn films with a tunable

Al-Mn Transition Edge Sensors for Cosmic Microwave Background Polarimeters

November 22, 2010
Author(s)
Daniel R. Schmidt, Hsiao-Mei Cho, Johannes Hubmayr, Peter J. Lowell, Michael D. Niemack, Galen C. O'Neil, Joel N. Ullom, Ki W. Yoon, Kent D. Irwin, W L. Holzapfel, M Lueker, E M. George, E Shirokoff
Superconducting transition edge sensors (TES) require superconducting films with transition temperatures (Tc)and properties that can be tailored to the particular requirements of individual applications. We have been developing Al-Mn films with a tunable

An Analytical Model for Pulse Shape and Electrothermal Stability in Two-Body Microcalorimeters

September 9, 2010
Author(s)
Douglas A. Bennett, Robert D. Horansky, Daniel R. Schmidt, Daniel S. Swetz, Leila R. Vale, Joel N. Ullom, Andrew Hoover, Michael W. Rabin, Nathan J. Hoteling
High resolution superconducting gamma-ray sensors show potential for the more accurate analysis of nuclear material. These devices are part of a larger class of microcalorimeters and bolometers based on transition edge sensors (TESs) that have two distinct

Quasiparticle Density of States Measurements in Clean Superconducting AlMn Alloys

May 6, 2010
Author(s)
Galen C. O'Neil, Daniel R. Schmidt, Nathan A. Tomlin, Joel N. Ullom
Aluminum doped with Manganese (AlMn) forms a superconducting alloy with the transition temperature suppressed by the added Manganese. We present quasiparticle density of states measurements on superconducting AlMn alloys made by current-voltage

Code-division SQUID multiplexing

April 23, 2010
Author(s)
Michael D. Niemack, Kent D. Irwin, Joern Beyer, Hsiao-Mei Cho, William B. Doriese, Gene C. Hilton, Carl D. Reintsema, Daniel R. Schmidt, Joel N. Ullom, Leila R. Vale
Multiplexed superconducting quantum interference device (SQUID) readout systems are a critical technology for measuring large arrays of superconducting transition-edge sensor (TES) detectors. Current successful SQUID multiplexing architectures are

Superconductor Science and Technology

February 22, 2010
Author(s)
Kent D. Irwin, Michael D. Niemack, Joern Beyer, Hsiao-Mei Cho, William B. Doriese, Gene C. Hilton, Carl D. Reintsema, Daniel R. Schmidt, Joel N. Ullom, Leila R. Vale
Multiplexed superconducting quantum interference device (SQUID) amplifiers have recently enabled the deployment of kilopixel arrays of superconducting transition-edge sensor (TES) detectors on a variety of receivers for astrophysics. Existing multiplexing

Time-of-flight mass spectrometry with latching Nb meander detectors

June 1, 2009
Author(s)
Brian Estey, James A. Beall, Gene C. Hilton, Kent D. Irwin, Daniel R. Schmidt, Joel N. Ullom, Robert E. Schwall
Mass Spectrometry is widely used for protein characterization, structural virology, drug discovery, and clinical chemistry. However the detection efficiency of existing detectors for mass spectrometry degrades rapidly as mass is increased and is only ~10-5

High resolution X-ray transition-edge sensor cooled by tunnel junction refrigerators and operated above the transition temperature

April 21, 2008
Author(s)
Nathan A. Tomlin, Galen C. O\'Neil, James A. Beall, Gene C. Hilton, Kent D. Irwin, Daniel R. Schmidt, Leila R. Vale, Joel N. Ullom
We demonstrate cooling of an X-ray transition-edge sensor (TES) using solid-state refrigerators based on normal-metal / insulator / superconductor (NIS) tunnel junctions. We are able to operate the TES at a bath temperature of 260 mK, which is 75 mK above

Density of states measurements of Al lightly doped with Mn

January 29, 2008
Author(s)
Galen O'Neil, Dan Schmidt, Nathan A. Tomlin, Joel Ullom, Kent D. Irwin, Anthony S. Williams, Gerry Arnold, Steve T. Ruggiero
Al lightly doped with Mn is a tunable superconductor, potentially useful in normalmetal/insulator/superconductor refrigerators. The superconducting transition temperature varies with Mn concentration and the density of states is like a BCS superconductor

A TDMA Hybrid SQUID Multiplexer

January 25, 2008
Author(s)
Carl D. Reintsema, James A. Beall, W.Bertrand (Randy) Doriese, William Duncan, S. L. Ferreira, Gene C. Hilton, Kent D. Irwin, Dan Schmidt, Joel Ullom, Leila R. Vale, Yizi Xu
We have developed a multiplexed read-out for transition edge sensors based on a hybrid time- and frequency-domain basis set, similar to that used in time-division multiple-access (TDMA) mobile phones. The hybrid basis set uses bandwidth more efficiently

Large array of multiplexed gamma-ray microcalorimeters for nuclear-materials analysis

January 24, 2008
Author(s)
W.Bertrand (Randy) Doriese, Joel Ullom, James A. Beall, William Duncan, S. L. Ferreira, Gene C. Hilton, Rob Horansky, Kent D. Irwin, John Mates, Carl D. Reintsema, Dan Schmidt, Leila R. Vale, Yizi Xu, Barry L. Zink, Michael W. Rabin, Minesh K. Bacrania, Stephen Lamont, Andrew Hoover, Clifford R. Rudy, Duc Vo, C. K. Stahle, Kevin R. Boyce, Larry E. Brown, Jonathan M. King, F. S. Porter
We are developing a gamma-ray spectrometer for the analysis of nuclear materials based on an array of superconducting transition-edge-sensor microcalorimeters. The instrument includes eight columns of time-division-SQUID multiplexing circuitry capable of