Below is an example of a Meta TEDS:
| | | |
|
| | Meta TEDS | | |
Field # | Description | Field Length (Bytes) | Field Type | Field Contents |
Data Structure related information | |
| |
1 | Meta-TEDS Length | 4 | U32 | 48 |
2 | IEEE 1451 Standards Family Working Group Number | 1 | U8 | 2 |
3 | TEDS Major Version Number | 2 | U16 | 2 |
4 | Future Extensions Key | 1 | U8 | 0 (NONE) |
5 | CHANNEL_ZERO Industry Extensions Key | 1 | U8 | 0 (NONE) |
6 | End User's Application Specific TEDS Key | 1 | U8 | 0 |
7 | Number of Implemented Channels | 1 | U8 | 1 |
8 | String Language Code | 1 | U8 | 0 |
9 | Bytes per Character | 1 | U8 | 1 |
Timing Related information | |
| |
10 | Worst Case Channel Data Model Length | 1 | U8 | 2 |
11 | Worst Case Channel Data Repetitions | 2 | U16 | 1 |
12 | Worst Case Channel Update Time | 4 | F32 | 2.00E-05 |
13 | Worst Case Channel Write Setup Time | 4 | F32 | 0 |
14 | Worst Case Channel Read Setup Time | 4 | F32 | 8.00E-05 |
15 | Input/Output Response Time | 4 | F32 | 5.00E-04 |
16 | Calibration TEDS Write Time | 4 | F32 | 0.00E+00 |
17 | Worst Case Data Clock Frequency | 4 | U32 | 2.00E+05 |
18 | Worst Case Channel Sampling Period | 4 | F32 | 2.00E-04 |
19 | Worst Case Unit Warm Up Time | 4 | F32 | 1 |
Channel grouping related information | | | |
20 | Channel Groupings Data Sub-Block Length | 2 | U16 | 0 |
21 | Number of Channel Groupings = G | 0 | U8 | - |
22 | Group Name Length | 0 | U8 | - |
23 | Group Name (<=255) | 0 | STRING | - |
24 | Group Type | 0 | U8 | - |
25 | Number of Group Members = N | 0 | U8 | - |
26 | Member Channel Numbers List = M(N) (<=255) | 0 | array of U8 | - |
Data integrity information | | | |
27 | Checksum for Meta-TEDS | 2 | U16 | 62856 |
Data Structure related information | | | |
28 | Meta-Identification TEDS Length | 4 | U32 | 310 |
Identification related information | | | |
29 | Manufacturer's Identification Length | 1 | U8 | 55 |
30 | Manufacturer's Identification (<=255) | 55 | STRING | Texas Instruments Incorporated Control Product Division |
31 | Model Number Length | 1 | U8 | 9 |
32 | Model Number (<=255) | 9 | STRING | EX3514.XX |
33 | Revision Code Length | 1 | U8 | 2 |
34 | Revision Code | 2 | STRING | 01 |
35 | Serial Number Length | 1 | U8 | 5 |
36 | Serial Number (<=255) | 5 | STRING | SN-01 |
37 | Data Code Length | 1 | U8 | 25 |
38 | Data Code (<=255) | 25 | STRING | November 1, 1995, Shift 1 |
39 | Product Description Length | 2 | U16 | 205 |
40 | Product Description (<=65535) | 205 | STRING | Description: Ratio metric Pressure Transducer |
|
| | | Part Number: EX3514.XX |
|
| | | Serial Number: SN-01 |
|
| | | Pressure Range: 0 to 3000 PSIA |
|
| | | Input Voltage: 5Vdc |
|
| | | Output Voltage 0 to 5 Vdc |
|
| | | Temperature Range: -40 To 85 degrees C |
| | | | |
Data Integrity information data sub-block | | | |
41 | Checksum for Meta-Identification TEDS | 2 | U16 | 38702 |
|
Back to TEDS | |