An official website of the United States government
Here’s how you know
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
Secure .gov websites use HTTPS
A lock (
) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.
Technical Study of the Sofa Super Store Fire-South Carolina, June 18, 2007 Volume II ***DRAFT FOR PUBLIC COMMENT*** (for final version, see NIST SP 1119, March 2011)
Published
Author(s)
Nelson P. Bryner, Anthony D. Putorti Jr., Stephen P. Fuss, Bryan W. Klein
Abstract
A fire occurred on the evening of June 18, 2007, in the Sofa Super Store in Charleston, SC. NIST analyzed the fire ground, consulted with other experts, and performed computer simulations of fire growth alternatives. Based on these analyses, the following sequence of events is likely to have occurred. A fire began in packing material and discarded furniture outside an enclosed loading dock area. The fire spread to the loading dock, then into both the retail showroom and warehouse spaces. During the early stages of the fire in the two latter locations, the fire spread was slowed by the limited supply of fresh air. This under-ventilation led to generation of a large mass of pyrolyzed and only partially oxidized effluent. The smoke and combustible gases flowed into the interstitial space below the roof and above the drop ceiling of the main retail showroom. As this space filled with unburned fuel, the hot smoke also seeped through the drop ceiling into the main showroom and formed a hot smoke layer below the drop ceiling. Up to this time, the extent of fire spread into the interstitial space was not visible to fire fighters in the store. If the fire spread had been visible to the fire fighters in the store, it would have provided a direct indication of a fire hazard in the showroom. Meanwhile, the fire at the back of the main showroom and the gas mixture below the drop ceiling were both still ventilation limited. When the front windows were broken out or vented, additional oxygen allowed the burn rate of the fire to intensify rapidly and to ignite the layer of unburned fuel below the drop ceiling. The fire swept from the rear to the front of the main showroom extremely quickly, and then into the west and east showrooms. Nine fire fighters were killed in the Sofa Super Store fire. Based on NIST s simulation of events, this report includes six recommendations to help mitigate such future losses.
Bryner, N.
, Putorti, A.
, Fuss, S.
and Klein, B.
(2010),
Technical Study of the Sofa Super Store Fire-South Carolina, June 18, 2007 Volume II ***DRAFT FOR PUBLIC COMMENT*** (for final version, see NIST SP 1119, March 2011), Special Publication (NIST SP), National Institute of Standards and Technology, Gaithersburg, MD, [online], https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=907221
(Accessed November 24, 2024)