Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Conventional vs. model-based measurement of patterned line widths from scanning electron microscopy profiles

Published

Author(s)

Francesc Salvat-Pujol, John S. Villarrubia

Abstract

Scanning electron microscopy (SEM) is a practical tool to determine the dimensions of nanometer-scale features. Conventional width measurements use arbitrary criteria, e.g., a 50 % threshold crossing, to assign feature boundaries in the measured SEM intensity profile. To estimate the errors associated with such a procedure, we have simulated secondary electron signals from a suite of line shapes consisting of 30 nm tall silicon lines with varying sidewall angle and corner rounding. Four different inelastic scattering models were employed in a state-of-the-art Monte Carlo simulation of electron transport to compute secondary electron image intensity profiles for each of the shapes. The 4 models were combinations of dielectric function theory with either the single-pole approximation (SPA) or the full Penn algorithm (FPA), and either with or without Auger electron emission. Feature widths were determined either by the conventional threshold method or by the model-based library (MBL) method, which is a fit of the simulated profiles to the reference model (FPA + Auger). On the basis of these comparisons we estimate the error in the measured width of such features by the conventional procedure to be as much as several nanometers. A 1 nm difference in the size of, e.g., a nominally 10 nm transistor gate would substantially alter its electronic properties. Thus, the conventional measurements do not meet the contemporary requirements of the semiconductor industry. In contrast, MBL measurements employing models with varying accuracy differed one from another by less than 1 nm. Thus, a MBL measurement is preferable in the nanoscale domain.
Citation
Ultramicroscopy
Volume
206

Keywords

Electron transport, Inelastic scattering of low-energy electrons, Nanoscale metrology, SEM, JMONSEL, Low-energy electron transport

Citation

Salvat-Pujol, F. and Villarrubia, J. (2019), Conventional vs. model-based measurement of patterned line widths from scanning electron microscopy profiles, Ultramicroscopy, [online], https://doi.org/10.1016/j.ultramic.2019.112819, https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=927238 (Accessed November 23, 2024)

Issues

If you have any questions about this publication or are having problems accessing it, please contact reflib@nist.gov.

Created July 30, 2019, Updated October 12, 2021