Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Investigating the Influence of Sampling Frequency on X-Space MPI Image Reconstructions

Published

Author(s)

Mark-Alexander Henn, Klaus Natorf Quelhas, Solomon I. Woods

Abstract

In this presentation we employ a direct X-space deconvolution to estimate particle distributions from MPI data. We report on how the accuracy of those estimations changes as a function of sampling frequency and compare the findings to the MPI core operator approach found in literature.
Proceedings Title
International Workshop on Magnetic Particle Imaging
Volume
9
Issue
1
Conference Dates
March 22-24, 2023
Conference Location
Aachen, DE

Keywords

Magnetic Particle Imaging, Inverse Problems, Modelling, Simulations

Citation

Henn, M. , Natorf Quelhas, K. and Woods, S. (2023), Investigating the Influence of Sampling Frequency on X-Space MPI Image Reconstructions, International Workshop on Magnetic Particle Imaging, Aachen, DE, [online], https://doi.org/10.18416/IJMPI.2023.2303042, https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=936210 (Accessed November 23, 2024)

Issues

If you have any questions about this publication or are having problems accessing it, please contact reflib@nist.gov.