Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications

NIST Authors in Bold

Displaying 801 - 825 of 2606

Electron and Hole Photoemission Detection for Band Offset Determination of Tunnel Field-Effect Transistor Heterojunctions

November 24, 2014
Author(s)
Wei Li, Qin Zhang, R. Bijesh, Oleg A. Kirillov, Yiran Liang, Igor Levin, Lianmao Peng, Xuelei Liang, S. Datta, David J. Gundlach, Nhan V. Nguyen
The electrical performance of a tunnel field-effect transistor depends critically on the band offset at their semiconductor heterojunction interface. Historically, it has been difficult to experimentally determine how the electronic bands align at the

Diode-array UV solar spectroradiometer implementing a digital micromirror device

November 20, 2014
Author(s)
Ari D. Feldman, Tim Burnitt, Geiland Porrovecchio, Marek Smid, Luca Egli, Julian Gr?bner, Katherine M. Nield
The solar ultraviolet spectrum captured by commercially available diode-array spectroradiometers is dominated by stray light from longer wavelengths with higher intensity. The implementation of a digital micromirror device in an array spectroradiometer has

Accurate determination of the size distribution for polydisperse, cationic metallic nanomaterials by asymmetric-flow field flow fractionation

November 13, 2014
Author(s)
Julien C. Gigault, Thao M. Nguyen, John M. Pettibone, Vincent A. Hackley
In this work we have developed and validated a methodology for determining the size distribution in polydisperse cationic nanoparticle (NP) samples using asymmetric-flow field flow fractionation (A4F), where known compositional influence of previously used

Influence of the central mode and soft phonon on the microwave dielectric loss near the strain-induced ferroelectric phase transitions in Sr n+1 uTi n uO 3n+1 u*

November 12, 2014
Author(s)
V. Goian, S. Kamba, D Nuzhnyy, Nathan Orloff, T. Birol, C.-H Lee, D. G. Schlom, James Booth
Recently, Lee et al. [1] used1% tensile strain to induce a ferroelectic instability in thin films of Srdn+1uTi nuO 3n+1u (n=1-6) phases. They showed that the Curie temperature T cu gradually increased with n, reaching 180 K for Sr7Ti6O19 (n=6). The

A Method of Determining Sphere Center to Center Distance Using Laser Trackers For Evaluating Laser Scanners.

November 11, 2014
Author(s)
Prem K. Rachakonda, Balasubramanian Muralikrishnan, Vincent D. Lee, Daniel S. Sawyer, Steven D. Phillips, John Palmateer
The Dimensional Metrology Group (DMG) at the National Institute of Standards and Technology (NIST) is involved in the development of documentary standards for volumetric performance evaluation of laser scanners. Typical evaluation of these scanners

THE CONSTRUCTION AND CHARACTERIZATION OF THE NIST-4 PERMANENT MAGNET SYSTEM

November 9, 2014
Author(s)
Leon S. Chao, Frank C. Seifert, Shisong Li, Darine El Haddad, Stephan Schlamminger, Jon R. Pratt
A watt balance is an electromagnetic force balancing instrument to realize the unit of mass at the kilogram level. The magnet system is one of the key components. Our group at the National Institute of Standards and Technology is currently building a next

Checking the Net Content of Packaged Goods (NIST HB 133-2015)

November 4, 2014
Author(s)
Linda D. Crown, David A. Sefcik, Lisa Warfield
This handbook has been prepared as a procedural guide for the compliance testing of net contents statements on packaged goods. Compliance testing of packaged goods is the determination of the conformance results of the packaging, distribution, and

NIST Micronutrients Measurement Quality Assurance Program Summer 2013 Comparability Studies: Results for Round Robin LXXIV Fat-Soluble Vitamins and Carotenoids in Human Serum and Round Robin 39 Ascorbic Acid in Human Serum

October 30, 2014
Author(s)
Jeanice M. Brown Thomas, David L. Duewer
The National Institute of Standards and Technology coordinates the Micronutrients Measurement Quality Assurance Program (MMQAP) for laboratories that measure fat- and water-soluble vitamins and carotenoids in human serum and plasma. This report describes

NIST Micronutrients Measurement Quality Assurance Program Winter 2013 Comparability Studies: Results for Round Robin LXXIII Fat-Soluble Vitamins and Carotenoids in Human Serum and Round Robin 38 Ascorbic Acid in Human Serum

October 30, 2014
Author(s)
Jeanice M. Brown Thomas, David L. Duewer
The National Institute of Standards and Technology coordinates the Micronutrients Measurement Quality Assurance Program (MMQAP) for laboratories that measure fat- and water-soluble vitamins and carotenoids in human serum and plasma. This report describes

NIST Micronutrients Measurement Quality Assurance Program Winter, Spring, and Fall 1994 Comparability Studies: Results for Round Robins XXX, XXXI, and XXXII Fat-Soluble Vitamins and Carotenoids in Human Serum and Round Robins 5 and 6 Ascorbic Acid in Huma

October 30, 2014
Author(s)
Jeanice M. Brown Thomas, Margaret C. Kline, Katherine E. Sharpless, S A. Margolis
The National Institute of Standards and Technology coordinates the Micronutrients Measurement Quality Assurance Program (MMQAP) for laboratories that measure fat- and water-soluble vitamins and carotenoids in human serum and plasma. This report describes

3D Monte Carlo modeling of the SEM: Are there applications to photomask metrology?

October 23, 2014
Author(s)
John S. Villarrubia, Andras Vladar, Michael T. Postek
The ability to model the effect of fields due to charges trapped in insulators with floating conductors has been added to JMONSEL (Java Monte Carlo simulator for Secondary Electrons) and applied to a simple photomask metal on glass geometry. These

Challenges of Irradiance-mode Spectral Response Measurements

October 16, 2014
Author(s)
Behrang H. Hamadani, John F. Roller, Brian P. Dougherty, Howard W. Yoon
Irradiance-mode spectral response measurements of solar cells are important because they provide a direct, reliable and accurate route for determination of the short circuit current (Isc) of solar cells under air mass 1.5 standard reference spectrum. In

TEST AND CALIBRATION OF DISPLACEMENT MEASURING LASER INTERFEROMETERS

October 15, 2014
Author(s)
Jack A. Stone Jr.
At the National Institute of Standards and Technology (NIST), we have a capability to calibrate and test laser interferometer systems used to measure displacements. Recently our calibration protocol has been modified so as to bring it into accord with a

DEVELOPMENT OF A MINIATURE, MULTICHANNEL, EXTENDED-RANGE FABRY-PEROT FIBER-OPTIC LASER INTERFEROMETER SYSTEM FOR LOW FREQUENCY SI-TRACEABLE DISPLACEMENT MEASUREMENT

October 12, 2014
Author(s)
Bartosz K. Nowakowski, Douglas T. Smith, Stuart T. Smith
Laser interferometry has become a staple of SI-traceable displacement measurement techniques. With decreasing cost per channel, miniaturization, and a multitude of commercially available off-the-shelf systems, these systems create ever more attractive

Photonic-assisted Endoscopic Analysis of W-band Waveguide

October 12, 2014
Author(s)
Jeffrey A. Jargon, DongJoon Lee, JaeYong Kwon, YoungPyo Hong
We demonstrate an endoscopic probing system to measure field distribution through a W-band waveguide. The electric fields propagating inside a WR-10 waveguide are measured utilizing W-band harmonics of a femtosecond laser with a minute photonic probe.
Displaying 801 - 825 of 2606