Certification of Elements in and Use of Standard Reference Material 3280 Multivitamin/Multielement Tablets

December 2, 2013
Author(s)
Gregory C. Turk, Katherine E. Sharpless, Steven J. Christopher, Danielle Cleveland, Russell D. Day, Stephen E. Long, Elizabeth A. Mackey, Anthony F. Marlow, Rick L. Paul, John R. Sieber, Rabia Oflaz, Laura J. Wood, Lee L. Yu, Rolf L. Zeisler, Stephen A. Wise, James H. Yen, E. Greene, J. Harnly, I-P Ho, Joseph M. Betz, R. Q. Thompson, Candace Jongsma
Standard Reference Material (SRM) 3280 Multivitamin/Multielement Tablets was issued by the National Institute of Standards and Technology (NIST) in 2009 and has certified and reference mass fraction values for 13 vitamins, 26 elements, and 2 carotenoids

Quantitative bottom-up proteomics depends on digestion conditions

December 2, 2013
Author(s)
Mark S. Lowenthal, Yuxue Liang, Karen W. Phinney, Stephen E. Stein
Accurate quantification is a fundamental requirement in the fields of proteomics and biomarker discovery, and for clinical diagnostic assays. To demonstrate the extent of quantitative variability in measurable peptide concentrations due to differences

Electro-Thermo-Mechanical Model for Bulk Acoustic Wave Resonators

November 30, 2013
Author(s)
Eduard Rocas, Juan C. Collado Gomez, Jordi Mateu, Nathan D. Orloff, James C. Booth, Robert Aigner
We present the electro-thermo-mechanical constitutive relations, expanded up to the third order, for a BAW resonator. The relations obtained are implemented into a circuit model, which is validated with extensive linear and nonlinear measurements. The

ToF-SIMS 3D Imaging of Native and Non-Native Species within HeLa Cells

November 26, 2013
Author(s)
Jeremy Brison, Michael A. Robinson, Danielle S. Benoit, Shinichiro Muramoto, Patrick S. Stayton, David G. Castner
In this study, a non-native chemical species, bromodeoxyuridine (BrdU), was imaged within single HeLa cells using time-of-flight secondary ion mass spectrometry (ToF-SIMS). The z-axis corrected 3D images were reconstructed that accurately portray the

Absolute line intensities for oxirane from 1420 to 1560 cm-1

November 15, 2013
Author(s)
F K. Tchana, M. Ngom, Agnes Perrin, Jean-Marie Flaud, Walter J. Lafferty, S. A. Ndiaye, El. A. Ngum
Absolute individual line intensities of numerous transitions of the fundamental ν2 and ν10 bands of oxirane (ethylene oxide, c-C2H4O) have been measured in the 1420-1560 cm-1 region using seven high- resolution Fourier transform spectra recorded at 0.002

Absolute line intensities for the nu3 band of oxirane (C2H4O)

November 15, 2013
Author(s)
Walter J. Lafferty, Jean-Marie Flaud, Fridolin Kwabia, A. Perrin, M. Ngom
Seven Fourier transform spectra of the ν3 band of oxirane (ethylene oxide) have been recorded with different pressures and used to derive individual line intensities. These line intensities were satisfactorily fit leading to accurate transition moment

Determination of Trace Sulfur in Biodiesel and Diesel Standard Reference Materials by Isotope Dilution Sector Field Inductively Coupled Plasma Mass Spectrometry

November 14, 2013
Author(s)
Steven J. Christopher, Stephen E. Long, Renata Amais, Joaquim N?ga
A method is described for quantification of sulfur at low concentrations on the order of 10 µg g-1 in biodiesel and diesel fuels using double isotope dilution and sector field inductively coupled plasma mass spectrometry (ID-SF-ICP-MS). Closed vessel

On the Determination of Carbon by PGAA

November 10, 2013
Author(s)
Rolf L. Zeisler, Rick L. Paul, Jeffrey A. Fagan, Zsolt R?vay, Stefan S?llradl
Determination of carbon was achieved with reduction of background in prompt gamma activation analysis.

Microsensor Analyses for Trace Targets over Extended Times in a Simulated Martian Environment

November 6, 2013
Author(s)
Kurt D. Benkstein, Phillip H. Rogers, Christopher B. Montgomery, Stephen Semancik, C. Jin, Baranidharan Raman
We have studied the performance of a chemical microsensor array in a simulated Martian environment, which involved a carbon dioxide-rich background with low oxygen content (0.15 %) at low pressure and temperature to mimic the conditions at the Martian

Methods for Optimizing and Extending the Performance of Chemiresistive Gas Microsensors

November 3, 2013
Author(s)
Kurt D. Benkstein, Alexander (. Vergara Tinoco, Christopher B. Montgomery, Baranidharan Raman, Stephen Semancik
This paper briefly describes varied concepts developed and implemented to enhance the performance of gas-phase chemical microsensors. The developments are illustrated for chemiresistive (MEMS) microdevices, and involve efficient, array-based approaches to

Fluctuation Enhanced Sensing (FES) with a Nanostructured Semiconducting Metal Oxide Film for Gas Detection and Classification

October 31, 2013
Author(s)
Bulent Ayhan, Chiman Kwan, Jin Zhou, Laszlo Kish, Kurt D. Benkstein, Phillip H. Rogers, Stephen Semancik
The feasibility of fluctuation-enhanced sensing (FES) for the detection and classification of different gases by using a single microsensor has been experimentally demonstrated. A nanostructured semiconducting metal oxide film has been used as a

Achieving Climate Change Absolute Accuracy in Orbit

October 28, 2013
Author(s)
Bruce Wielicki, Joseph P. Rice
The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission will provide a metrology laboratory in orbit for the purpose of accurately measuring and attributing climate change. CLARREO measurements establish new climate change benchmarks

Connection between thermodynamics and dynamics of simple fluids in highly attractive pores

October 25, 2013
Author(s)
William P. Krekelberg, Vincent K. Shen, Daniel W. Siderius, Thomas M. Truskett, Jeffrey R. Errington
We investigate the structural and diffusive dynamics properties of a model fluid in highly-absorptive cylindrical pores. At subcritical temperatures, self diffusion displays three distinct regimes as a function of average pore density ρ: 1) a decrease in

Spectral line shapes investigation with Pound-Drever-Hall-locked frequency-stabilized cavity ring-down spectroscopy

October 23, 2013
Author(s)
A. Cygan, S. Wojtewicz, J. Domyslawska, Piotr Maslowski, Katarzyna E. Bielska, M. Piwinski, K. Stec, R.S. Trawinski, F Ozimek, C. Radzewicz, Hisashi Abe, T. Ido, Joseph T. Hodges, D Lisak, R. Ciurylo
A review of recent experiments involving a newly developed Pound-Drever-Hall-locked frequency-stabilized cavity ring-down spectroscopy (PDH-locked FS-CRDS) system is presented. By comparison to standard FS-CRDS, the PDH lock of the probe laser to the ring

Measurement, Standards, and Data Needs for CO2 Capture Materials: A Critical Review

October 21, 2013
Author(s)
Laura Espinal, Dianne L. Poster, Winnie K. Wong-Ng, Andrew J. Allen, Martin L. Green
The commercial deployment of cost-effective carbon capture technology is hindered partially by the lack of a proper suite of materials-related standards, data, and measurement methods, which would provide critical information for the systematic design of

Isotope Dilution Mass Spectrometry For Quantitative Elemental Analysis Of Powdered Samples By Radiofrequency Pulsed Glow Discharge Time Of Flight Mass Spectrometry

October 15, 2013
Author(s)
John L. Molloy, Julian Malherbe, Fanny Claverie, Beatriz Fernandez, Aitor Alvarez-Toral, Alfredo Sanz-Medel, Rosario Pereiro
In recent years particular effort is being devoted to the development of pulsed glow discharges (PGDs) for mass spectrometry because this powering operation mode could offer important ionization analytical advantages. However, the capabilities of

Time-Resolved Infrared Studies of a Trimethylphosphine Model Derivative of [FeFe]-Hydrogenase

October 1, 2013
Author(s)
Edwin J. Heilweil, Christopher J. Stromberg, Melissa Johnson, James Thuman, Roger G. Letterman, Webster E. Charles
Model compounds that structurally mimic the hydrogen-producing active site of [FeFe] hydrogenases have been explored. In order to explore potential ground-state electronic structure effects on reaction mechanisms compared to hexacarbonyl derivatives, the

Rapid scan absorption spectroscopy using a waveform-driven electro-optic phase modulator in the 1.6- 1.65 ym region

September 25, 2013
Author(s)
Kevin O. Douglass, Stephen Maxwell, Gar W. Truong, Roger D. van Zee, Joseph T. Hodges, David Long, David F. Plusquellic
A method is reported for performing fast optical frequency scans over a bandwidth of 36.9 GHz and at a sweep rate of 40 kHz using a single second-order sideband from an electro-optic phase modulator driven by an arbitrary waveform generator. Single

Effects of Desialylation on Human alpha1-Acid Glycoprotein-Ligand Interactions

September 16, 2013
Author(s)
Richard Y. Huang, Jeffrey W. Hudgens
Human α1-Acid Glycoprotein (AGP), an acute phase glycoprotein, exists predominantly in blood. With its ability to bind basic, lipophilic, and acidic drugs, AGP has served as a drug carrier. It has been shown that the carbohydrate composition of AGP changes
Displaying 801 - 825 of 2028