Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications by: Stephen Wise (Assoc)

Search Title, Abstract, Conference, Citation, Keyword or Author
Displaying 26 - 50 of 822

Development of a new reversed-phase liquid chromatography and fluorescence method with multichannel selective wavelength detection for the analysis of benzo[a]pyrene and six of its isomers

September 28, 2018
Author(s)
Walter B. Wilson, Stephen A. Wise, Lane C. Sander
The baseline separation of benzo[a]pyrene in complex samples via reversed-phase liquid chromatography (RPLC) is particularly challenging due to the potential for interferences from other molecular mass 252 (MM, g/mol) polycyclic aromatic hydrocarbons (PAHs

Determination of polycyclic aromatic hydrocarbons with molecular mass 302 in standard reference material 1597a by reversed-phase liquid chromatography and stop-flow fluorescence detection

June 21, 2018
Author(s)
Hugh Hayes, Walter Wilson, Lane Sander, Stephen Wise, Andres Campiglia
The identification of isomeric polycyclic aromatic hydrocarbons (PAHs) in complex samples via reversed-phase liquid chromatography (RPLC) with fluorescence detection (FL) is normally based on matching the chromatographic retention times of suspected peaks

Final Report for CCQM-K6.2: Determination of Total Cholesterol in Human Serum

June 7, 2018
Author(s)
Stephen Wise, Karen W. Phinney, David L. Duewer
Cholesterol is one of the most frequently measured substances in human blood/serum to assist in assessing the health status of individuals. Because of its clinical significance, CCQM-K6 Determination of Cholesterol in Serum was completed in 2000 as one of

Qualitative characterization of three combustion-related standard reference materials for polycyclic aromatic sulfur heterocycles and their alkyl-substituted derivatives via gas chromatography/mass spectrometry

May 7, 2018
Author(s)
Walter Wilson, Hugh Hayes, Andres Campiglia, Stephen Wise
This study represents the most comprehensive qualitative characterization of three combustion- related standard reference materials (SRMs) for polycyclic aromatic sulfur heterocycles (PASHs) and some alkyl-substituted (alkyl-) derivatives to date: SRM

Normal-phase liquid chromatography retention behavior of polycyclic aromatic sulfur heterocycles (PASHs) and alkyl-substituted PASH isomers on an aminopropyl stationary phase

December 14, 2017
Author(s)
Walter Wilson, Hugh Hayes, Lane Sander, Andres Campiglia, Stephen Wise
Retention indices for 67 polycyclic aromatic sulfur heterocycles (PASHs) and 80 alkyl- substituted PASHs were determined using normal-phase liquid chromatography (NPLC) on a aminopropyl (NH2) stationary phase. The retention behavior of PASH on the NH2

Gas Chromatographic Retention Behavior of Polycyclic Aromatic Hydrocarbons (PAHs) and Alkyl- Substituted PAHs on Two Stationary Phases of Different Selectivity

November 8, 2017
Author(s)
Federica Nalin, Lane C. Sander, Walter B. Wilson, Stephen A. Wise
Retention indices (RIs) for 45 polycyclic aromatic hydrocarbons (PAHs) and 63 methyl- substituted PAHs were determined by gas chromatography – mass spectrometry (GC-MS) using two different stationary phases: a 50% (mole fraction) phenyl-substituted

Development of a Cigarette Tobacco Filler Standard Reference Material

September 20, 2017
Author(s)
Lane C. Sander, Jeanita Pritchett, Laura J. Wood, Brian Lang, Stephen Wise, Matt J. Walters, T. Phillips, M. J. Holman, G. Lee, J. Lisko, B. Lane, L. Valentin, B. Kimbrell, S. Kuklenyik, S. Stanfill, C. Watson
A new tobacco filler Standard Reference Material (SRM) has been issued by the National Institute of Standards and Technology (NIST) in September 2016 with certified and reference mass fraction values for nicotine, N-nitrosonornicotine (NNN), 4-

Baseline Assessment of 25-Hydroxyvitamin D Assay Performance: A Vitamin D Standardization Program (VDSP) Interlaboratory Comparison Study

August 18, 2017
Author(s)
Christopher T. Sempos, Stephen Wise, Karen W. Phinney, Susan Tai, Johanna Camara, Gary L. Myers, Ramon Durazo-Arvizu, Lu Tian, John H. Eckfeldt, Andrew N. Hoofnagle, W. Greg Miller, Lorin M. Bachmann, Ian S. Young, J Pettit, G. Caldwell, A Liu, S P. Brooks, K. Sarafin, M. Thamm, C. Scheidt-Nave, G. B. Mensink, M. Busch, M. Rabenberg, Kevin Cashman, Mairead Kiely, Michael Kinsella, K Galvan, J. Y. Zhang, K OH, S. W. Lee, C. L. Jung, L. Cox, G. Goldberg, K. Guberg, S. Meadows, A. Prentice, G. Swan, A. Tedstone, Graham D. Carter, Julia C. Jones, P. Brannon, R. M. Lucas, P. M. Crump, Glenville Jones, E. Cavalier, Joyce Merkel, J. M. Betz
The Vitamin D Standardization Program (VDSP) coordinated an interlaboratory study to assess the comparability of measurements of total 25-hydroxyvitamin D [25(OH)D] in human serum, which is the primary marker of vitamin D status. A set of 50 individual