Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications by: Pavel Kabos (Fed)

Search Title, Abstract, Conference, Citation, Keyword or Author
Displaying 176 - 200 of 261

Einstein-de Haas effect in a NiFe film deposited on a microcantilever

September 18, 2006
Author(s)
Thomas Mitchell (Mitch) Wallis, John M. Moreland, Pavel Kabos
A new methods is presented for determining the magetomechanical ratio, g', in a thin ferromagnetic film deposited on a microcantilever via measurement of the Einstein-de Haas effect. An alternating magnetic field applied in the plane of the cantilever and

Ferromagnetic resonance linewidth in metallic thin films: Comparison of measurement methods

May 22, 2006
Author(s)
Sangita S. Kalarickal, Pavol Krivosik, Mingzhong Wu, C E. Patton, Michael Schneider, Pavel Kabos, Thomas J. Silva, John P. Nibarger
Strip line (SL), vector network analyzer (VNA), and pulsed inductive microwave magnetometer (PIMM) techniques were used to measure the ferromagnetic resonance (FMR) linewidth for a series of Permalloy films with thicknesses of 50 and 100 nm. The SL-FMR

Structure, ferromagnetic resonance and permeability of nanogranular fe-Co-B-Ni films

May 16, 2006
Author(s)
Pasquale Massimo, Celegato Federica, Coisson Marco, Magni Alessandro, Perero Sergio, Pavel Kabos, Teppati Valeria, Han Suk Hee, Kim Jongryoul, Lim Sang Ho
The static and microwave magnetic properties of soft nanogranular (Fe0.7)Co0.3)71B22Ni films with a 2T saturation magnetization are presented as a function of thickness, ranging from 135 to 235 nm. Microwave permeability values from 10 to 50 are measured

Near-Field Imaging of High Frequency Magnetic Fields with Calorimetric Cantilevers Probes

April 21, 2006
Author(s)
Simone Lee, Y. C. Lee, Thomas Mitchell (Mitch) Wallis, John M. Moreland, Pavel Kabos
Calorimetric probes for near-field imaging of high-frequency (1-20 GHz) magnetic fields were fabricated by depositing patterned metal structures on micromachined, dielectric multilayer cantilevers. In the presence of high-frequency magnetic fields, the

Realization of a Controllable Metafilm (''Smart Surface'') Composed of Resonant Magnetodielectric Particles: Measurements and Theory

November 1, 2005
Author(s)
Christopher L. Holloway, Pavel Kabos, Mohamed Mohamed, Edward Kuester, Michael D. Janezic, James R. Baker-Jarvis
In previous work, we derived generalized sheet-transition conditions (GSTCs) for the average electromagnetic fields across a metafilm, which, when properly designed, can have certain desired reflection and transmission properties. A metafilm is the two

Microwave Power Imaging with Ferromagnetic Films Incorporated in Bimaterial Cantilevers

November 1, 2004
Author(s)
Thomas Mitchell (Mitch) Wallis, John M. Moreland, Billy F. Riddle, Pavel Kabos
We report an imaging technique that uses ferromagnetic films incorporated in bimaterial cantilevers for spatially resolved calorimetric detection of microwaves emitted by sources of high frequency (4 to 20 GHz) radiation. The ferromagnetic film absorbs

Multiport Investigation of the Coupling of High-Impedance Probes

November 1, 2004
Author(s)
Dylan F. Williams, Pavel Kabos, Uwe Arz
We used an on-wafer measurement technique that combines two- and three-port frequency-domain mismatch corrections in order to characterize the influence of a high-impedance probe on a device under test. The procedure quantifies the probe’s load of the