Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications by: Rob Horansky (Fed)

Search Title, Abstract, Conference, Citation, Keyword or Author
Displaying 51 - 59 of 59

Anomalous thermal behavior in microcalorimeter gamma-ray detectors

July 20, 2009
Author(s)
Robert D. Horansky, James A. Beall, Kent D. Irwin, Joel N. Ullom
Improving the resolution of gamma-ray detectors is important for many fields, including determinations of the Lamb shift in atoms with high atomic numbers , nuclear treaty verification , and environmental monitoring. High-purity germanium detectors are

Improved Isotopic Analysis With a Large Array of Gamma-Ray Microcalorimeters

June 30, 2009
Author(s)
Nikhil Jethava, Joel N. Ullom, Douglas A. Bennett, William B. Doriese, James A. Beall, Gene C. Hilton, Robert D. Horansky, Kent D. Irwin, Eric Sassi, Leila R. Vale, Minesh K. Bacrania, Andrew Hoover, P. J. Karpius, Michael W. Rabin, Clifford R. Rudy, Duc T. Vo
We present results from the largest array of gamma-ray microcalorimeters operated to date. The microcalorimeters consist of Mo/Cu transition-edge sensors with attached Sn absorbers. The detector array contains 66 pixels each with an active area 2.25 mm 2

Improved Isotopic Analysis with a Large Array of Gamma-ray Microcalorimeters

June 30, 2009
Author(s)
Nikhil Jethava, Joel N. Ullom, Douglas A. Bennett, William B. Doriese, James A. Beall, Gene C. Hilton, Robert D. Horansky, Kent D. Irwin, Eric Sassi
We present results from the largest array of gamma-ray microcalorimeters operated to date. The microcalorimeters consist of Mo/Cu transition-edge sensors with attached Sn absorbers. The detector array contains 66 pixels each with an active area 2.25 mm2

Ultra-high resolution alpha particle spectroscopy using calorimetry

September 23, 2008
Author(s)
Robert D. Horansky, Joel N. Ullom, James A. Beall, Gene C. Hilton, Kent D. Irwin, Don Dry, Beth Hastings, Stephen Lamont, Clifford R. Rudy, Michael W. Rabin
Calorimetry has been used since the late 1700?s to measure the heat output of physical processes ranging from chemical reactions to the respiration of organisms . Calorimetry is performed by measuring the temperature change caused by heat release into a

Analysis of Nuclear Material by Alpha Spectroscopy with a Transition-Edge Microcalorimeter

January 26, 2008
Author(s)
Rob Horansky, Joel Ullom, James A. Beall, Gene C. Hilton, Kent D. Irwin, Leila R. Vale, Don Dry, Stephen Lamont, Clifford R. Rudy, Michael W. Rabin
We present measurements from a cryogenic microcalorimeter designed to detect alpha particles. The enhanced resolution of microcalorimeter alpha detectors will provide new capabilities for actinide analysis. We demonstrate a spectral resolution of 2.4 keV

Large array of multiplexed gamma-ray microcalorimeters for nuclear-materials analysis

January 24, 2008
Author(s)
W.Bertrand (Randy) Doriese, Joel Ullom, James A. Beall, William Duncan, S. L. Ferreira, Gene C. Hilton, Rob Horansky, Kent D. Irwin, John Mates, Carl D. Reintsema, Dan Schmidt, Leila R. Vale, Yizi Xu, Barry L. Zink, Michael W. Rabin, Minesh K. Bacrania, Stephen Lamont, Andrew Hoover, Clifford R. Rudy, Duc Vo, C. K. Stahle, Kevin R. Boyce, Larry E. Brown, Jonathan M. King, F. S. Porter
We are developing a gamma-ray spectrometer for the analysis of nuclear materials based on an array of superconducting transition-edge-sensor microcalorimeters. The instrument includes eight columns of time-division-SQUID multiplexing circuitry capable of

Multiplexed microcalorimeter arrays for precision measurements from microwave to gamma-ray wavelengths

August 21, 2007
Author(s)
Joel Ullom, W.Bertrand (Randy) Doriese, James A. Beall, William Duncan, S. L. Ferreira, Gene C. Hilton, Rob Horansky, Kent D. Irwin, Terrence J. Jach, John Mates, Nathan A. Tomlin, Galen O'Neil, Carl D. Reintsema, Nicholas Ritchie, Dan Schmidt, Leila R. Vale, Yizi Xu, Barry L. Zink, Andrew Hoover, Clifford R. Rudy, Derek Tournear, Duc Vo, Michael W. Rabin
Cryogenic microcalorimeters are a promising technology for ultrasensitive measurements of electromagnetic radiation from microwave to gamma-ray wavelengths. Cryogenic microcalorimeters derive their exquisite sensitivity from the minimal thermal noise at

A 14-pixel, multiplexed array of gamma-ray microcalorimeters with 47 eV energy resolution at 103 keV

May 9, 2007
Author(s)
W.Bertrand (Randy) Doriese, Joel Ullom, James A. Beall, William Duncan, S. L. Ferreira, Gene C. Hilton, Rob Horansky, Kent D. Irwin, John Mates, Carl D. Reintsema, Leila R. Vale, Yizi Xu, Barry L. Zink, Andrew Hoover, Michael W. Rabin, Clifford R. Rudy, Duc Vo
We present a prototype for a high-energy-resolution, high-count-rate, gamma-ray spectrometer intended for nuclear forensics and international nuclear safeguards. The prototype spectrometer is an array of 14 transition-edge-sensor microcalorimeters with an

Demonstration and modeling of an array-compatible TES microcalorimeter gamma-ray detector with 42 eV energy resolution at 103 keV

September 20, 2006
Author(s)
Barry L. Zink, Joel Ullom, James A. Beall, Kent D. Irwin, W.Bertrand (Randy) Doriese, William Duncan, S. L. Ferreira, Gene C. Hilton, Rob Horansky, Carl D. Reintsema, Leila R. Vale
We describe a microcalorimeter gamma-ray detector with measured energy resolution of 42 eV full width at half maximum for 103 keV photons. This detector consists of a thermally isolated superconducting transition-edge thermometer and a superconducting bulk