This 5 day OWM volume metrology seminar is designed to enable metrologists to apply fundamental measurement concepts to volume calibrations. A large percentage of time is spent on hands-on measurements, applying procedures and equations discussed in the classroom. The seminar focuses on the comprehension and application of the procedures, the equations, calculations involved, and the operation of the laboratory equipment, review of publications, standards, specifications, and tolerances relevant to the measurements. Training covers volume calibration procedures published in NISTIR 7383 as well as supplemental procedures from NISTIR 6969. Specific volume transfer procedures include SOP 14, 16, 18, 19, and 21. SOP 14 is a gravimetric volume procedure and builds on the mass procedures SOP 2 and SOP 4 (thus the prerequisite for the Mass Metrology Seminar). This course is suitable for the calibration of volumetric standards for NIST HB 105-2, HB 105-3, HB 105-4, and concepts related to HB 105-7. The entire seminar incorporates statistical analysis, process measurement control methods, uncertainty analyses, traceability assessments, and generation of ISO/IEC 17025 compliant calibration certificates for all measurements made during the seminar and builds on the concepts covered in the Fundamentals of Metrology and Mass seminars.
At the end of this seminar, using Standard Operating Procedures 2, 14, 17, 18, 19, 21, 29 and 30 and Good Measurement Practices 3, 11, and 13, participants will be able to:
Several notebooks and files (spreadsheets and documents) are provided.
Successful completion of the Fundamentals of Metrology Seminar AND the Mass Metrology Seminar are required. The Volume Metrology seminar is built on the concepts learned during the Fundamentals of Metrology Seminar, applying units, measurement uncertainty, measurement assurance, traceability and Quality Management System concepts as well as the buoyancy concepts and precision mass calibrations that are required for successful completion of gravimetric volume calibrations.
To receive a Certificate for this course, successful completion requires participants to attend 100 % of the course, actively participate (e.g., take notes, engage in discussions, ask questions), complete all classroom, homework*, and application exercise assignments, submit assigned calibration certificates, and receive at least 70 % on the final written exam. A written final exam will contribute 50 percent of the grade and the class and laboratory exercises will be 50 percent of the grade. A passing grade (70 % minimum) on both portions is required to obtain a training certificate that indicates “successful completion”.
*Homework note: students generally report taking one to two hours for homework each night.
State weights and measures officials and industry metrologists.
You will need to bring a 10-digit scientific calculator to use during this seminar. Participants MUST be familiar with the use of the hand-held scientific calculator. Additionally, use of a laptop or tablet PC is essential to success in the seminar. Participants must have access to Microsoft Excel (versions 2010 to present are acceptable) and be able to open and use template Excel workbooks that will be provided on either CD-ROM or USB media. You must also be able to save/store files to USB media devices to facilitate printing. Participants must be able to save/store files to USB media devices or CD-RW to facilitate printing and turning in homework assignments; if not able to use USB media, participants must be able to connect their laptop to a printing device by cable or BlueTooth and be able to upload files to a NIST Box file-sharing service and download files from a secure Google Drive.
NIST OWM has a number of other training opportunities scheduled. For more information: